Permit: T17BU00270

Parcel: 141190160

Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Date Description Inspector Results Comments
08/14/2017 POOL/SPA PLUMBING Approved
08/11/2017 POOL/SPA PLUMBING Not ready for Inspection Install HB vacuum breaker.
Provide code approved Upstream piping for pool fill Backflow assembly. Test and protect assembly.
08/10/2017 POOL/SPA PLUMBING Not ready for Inspection IVRS - Inspection :*
07/06/2017 POOL/SPA PLUMBING Partial Approval Gas and Electric to BBQ are only 6" deep and will require concrete protection to final.
AVB may not have a valve down stream; install a PVB or RPA for poolfill, provide test report and freeze protection.
Test pool fill pipe and remove rocks touching all pipes prior to backfill.