Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T17BU00112

Parcel: 140376020


Addresses:

6918 S GOSHAWK DR

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
10/06/2017 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
09/19/2017 POOL/SPA FINAL/BARRIER Partial Approval IVRS - Inspection :*
09/14/2017 POOL/SPA FINAL/BARRIER Denied Gates shall self close, correct latch, window and door alarms shall be UL2017, secure grounding conductor and flex conduit whips to wall, label breakers. Install high hazard backflow protection, PVB, provide test certification and freeze protection, hose bib vacuum breaker, UV protection.