Permit: T17BU00112

Parcel: 140376020


Addresses:

6918 S GOSHAWK DR

Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Date Description Inspector Results Comments
09/19/2017 POOL/SPA PLUMBING Approved IVRS - Inspection :*
09/14/2017 POOL/SPA PLUMBING Denied Gates shall self close, correct latch, window and door alarms shall be UL2017, secure grounding conductor and flex conduit whips to wall, label breakers. Install high hazard backflow protection, PVB, provide test certification and freeze protection, hose bib vacuum breaker, UV protection.
08/23/2017 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*