Permit: T16OT01129

Parcel: 141220280


Addresses:

9255 S RITA RD


Inspection Status: Approved

Inspection History: SIGN EXCAVATION

Permit Number - T16OT01129

Inspection Description - SIGN EXCAVATION

Inspection Status - Approved

Date Description Inspector Results Comments
04/12/2017 SIGN EXCAVATION Approved FOOTING AND SETBACK PER PLAN
03/07/2017 SIGN EXCAVATION Denied NO PAPERWORK ON SITE, NO CONTACT INFO
03/07/2017 SIGN EXCAVATION Denied CONTRACTOR - THE PLACEMENT OF THIS SIGN IS WITHIN THE 100' YEAR DRAINAGE ON SITE, WHICH WAS NOT SHOWN ON YOUR SUBMITTED PLANS. FURTHER, YOUR SUBMITTED PLANS DO NOT SHOW THE HEIGHT OF THE SIGN FROM THE TOP OF ADJACENT STREET CURB. FOOTER AND PIPE MAY BE AFFECTED.

MODIFICATIONS ARE REQUIRED. PERMIT IS UNABLE TO PROCEED FURTHER UNTIL THE FOLLOWING IS ADDRESSED.
PER INQUIRY FROM INSPECTIONS DIVISION, SIGNS STAFF PULLED THE DEVELOPMENT PLAN (SHOWS GRADING) AND CONSULTED OUR ENGINEERING DIVISION. THE SIGN SHOULD EITHER BE MOVED OUT OF THE 100' YEAR FLOOD AREA, OR FURTHER ENGINEERING CALCULATIONS SUBMITTED TO SUPPORT THE SIGN INSTALLATION WITHIN THE DRAINAGE AREA WILL BE SAFELY ABLE TO HANDLE THE POWER OF A 100' YEAR FLOW EVENT, ALL ELECTRIC TO BE 1' ABOVE THE MAXIMUM 100' YEAR EVENT FLOW LINE, AND THAT VOLUME OF THE SIGN WILL NOT DISTURB THE 100' YEAR FLOW TO SPILL OVER INTO ADJACENT RIGHT OF WAY. THIS IS PER BOTH THE FLOODPLAIN MANUAL AND THE DRAINAGE MANUAL IN CONSUTLATION WITH ENGINEER PAUL BAUGHMAN.