Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SITE REVIEW
Permit Number - T16OT00711
Inspection Description - SIGN SITE REVIEW
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/06/2016 | SIGN SITE REVIEW | Approved | ||
06/16/2016 | SIGN SITE REVIEW | Partial Approval | T16OT00711 232 W Flores St Review date: June 16, 2016 Proposed repair/restoration of nonconforming pole sign per Historic Landmark Sign (HLS) case: T16SA00108 Sign Review/H.Thrall Structural/ E.Newcomb Outdoor Lighting Code/H.Thrall & D. Santa Cruz Electrical/ D. Santa Cruz Sign Review: Reviewer is familiar with purpose for permit application, which matches approved HLS treatment plan and conditions of approval of case T16SA00108. 1) Sheet 1, color photo renderings will not scan and a description of work is needed for records and inspections on this permit. Add note on SHEET 1 "repair existing sign - paint/neon/electric as needed per Historic Landmark Sign Case T16SA00108". Structural review: Acknowledged existing sign, existing support pole - "welded collar" on sheet 2 is new. Appears field welding. 1) If welded collar is not for sign cabinet support but to stabilize cabinet into one position, no engineering required. Provide clarification note on SHEET 1 under description of work. Provide sealed engineering calculations if collar is used for cabinet support. 2) Field welds require special inspection, regardless of whether engineering calcs needed. Fill out form (link below) for field welding inspection to be done by qualified inspector. Return form to structural reviewer for approval of chosen inspector. Form: https://www.tucsonaz.gov/files/pdsd/forms/Special_Inspection_Certificate_1-9-14.pdf *Note - in this case, chosen field weld inspector may be qualified to seal certificate - or his/her supervisor. (List of inspectors is maintained by the Town of Oro Valley, and is found here under company name or inspector's name) https://www.orovalleyaz.gov/town/departments/development-and-infrastructure-services/inspections-and-code-compliance Outdoor Lighting Code review: 103.3 Historic Landmark Signs. Lighting is exempt except for Sect 403 Curfew Requirements. 1) Acknowledged a note on plan timer is to be provided, note location of timer for inspector. Electrical review: Approved |