Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T16OT00711

Parcel: 115052410


Addresses:

232 W FLORES ST


Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T16OT00711

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
07/06/2016 SIGN SITE REVIEW Approved
06/16/2016 SIGN SITE REVIEW Partial Approval T16OT00711
232 W Flores St
Review date: June 16, 2016
Proposed repair/restoration of nonconforming pole sign per
Historic Landmark Sign (HLS) case: T16SA00108

Sign Review/H.Thrall
Structural/ E.Newcomb
Outdoor Lighting Code/H.Thrall & D. Santa Cruz
Electrical/ D. Santa Cruz

Sign Review: Reviewer is familiar with purpose for permit application, which matches approved HLS treatment plan and conditions of approval of case T16SA00108.
1) Sheet 1, color photo renderings will not scan and a description of work is needed for records and inspections on this permit. Add note on SHEET 1 "repair existing sign - paint/neon/electric as needed per Historic Landmark Sign Case T16SA00108".

Structural review: Acknowledged existing sign, existing support pole - "welded collar" on sheet 2 is new. Appears field welding.
1) If welded collar is not for sign cabinet support but to stabilize cabinet into one position, no engineering required. Provide clarification note on SHEET 1 under description of work. Provide sealed engineering calculations if collar is used for cabinet support.
2) Field welds require special inspection, regardless of whether engineering calcs needed. Fill out form (link below) for field welding inspection to be done by qualified inspector. Return form to structural reviewer for approval of chosen inspector.
Form: https://www.tucsonaz.gov/files/pdsd/forms/Special_Inspection_Certificate_1-9-14.pdf

*Note - in this case, chosen field weld inspector may be qualified to seal certificate - or his/her supervisor.

(List of inspectors is maintained by the Town of Oro Valley, and is found here under company name or inspector's name) https://www.orovalleyaz.gov/town/departments/development-and-infrastructure-services/inspections-and-code-compliance

Outdoor Lighting Code review: 103.3 Historic Landmark Signs. Lighting is exempt except for Sect 403 Curfew Requirements.
1) Acknowledged a note on plan timer is to be provided, note location of timer for inspector.

Electrical review: Approved