Permit: T16OT00119

Parcel: 11520007B

Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T16OT00119

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
02/03/2016 SIGN SITE REVIEW Approved
01/28/2016 SIGN SITE REVIEW Correction Required Additional review is required for all exposed illuminated signs (Neon) per2012 City of Tucson/Pima County Outdoor Lighting Code http://cms3.tucsonaz.gov/sites/default/files/dsd/Codes-Ordinances/2012_outdoor_lighting_code_.pdf Submit Application to City of Tucson Electrical Representative for review and possible comments.

The following applies to exposed neon lighting:

Exposed lamp sign fixtures shall conform to the City of Tucson Outdoor Lighting Code (Ord #10963) as listed at section 501.4. Compare total outdoor fixture output to the budget based on property size and zone location (Table 401.1). Include all existing and proposed fixtures in the calculation.

The rated color temperature of proposed fixtures shall not exceed 3500K, Section 402 and intensity of 200 nits, Section 501.5. Notate the plans, or provide manufacturer spec sheet with color temperature rating.

Provide a control schedule in conformance with Table 501.5 limiting hours of illumination. The curfew time is 12:00 A.M. unless business activities continue after this time. Notate the closing time.

The 2012 Outdoor Lighting Code may be found on The City of Tucson Website under: www.tucsonaz.gov/pdsd; Codes, Standards, Ordinances & Guidelines; Building Codes.