Permit: T16EX00624


Addresses:

1501 N CAMPBELL AV

Inspection Status: Approved

Inspection History: TDOT-EXCAV GENERAL INSPECTION

Date Description Inspector Results Comments
09/13/2016 TDOT-EXCAV GENERAL INSPECTION Approved Final. No Further Concerns.
08/03/2016 TDOT-EXCAV GENERAL INSPECTION Continued Form check on ADA Ramps on Drachman/Vine. Need to remove existing wing curb to make elevations work. Ok to pour curb after removal.
07/11/2016 TDOT-EXCAV GENERAL INSPECTION Continued Discussed replacement of 2 ADA ramps removed/damaged by excavation.
03/22/2016 TDOT-EXCAV GENERAL INSPECTION Continued Final pave. Temp pave on SW and some curb area until phase 2.
03/21/2016 TDOT-EXCAV GENERAL INSPECTION Continued Slurry set up ready to pave Sat morning 7am.
03/17/2016 TDOT-EXCAV GENERAL INSPECTION Continued Flint from UCCo says cant get CLSM #2 from plant. Ok to use product #400205 2 sack sand slurry mix instead per Lance P.
03/14/2016 TDOT-EXCAV GENERAL INSPECTION Continued Emailed Flint from UCCo the spec on PAG 2 AC. Call from Andi (UCCo) to confirm PAG 2 spec.
03/14/2016 TDOT-EXCAV GENERAL INSPECTION Continued Site visit to view progress.
03/10/2016 TDOT-EXCAV GENERAL INSPECTION Continued Met with Tom A. and UCCo. On site. CLSM #2 backfill on all trenches. TTop asphalt patches on all trenching in roadway.