Case: T16DV03504

Parcel: 115050720


Addresses:

240 W SAHUARO ST


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T16DV03504

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
06/13/2016 INSP - INITIAL CODE ENFORCMENT Approved Minimum housing inspection; Inspectors Goodman, Hollander, and Pumphrey on site. This is a followup to condemnations issued on 06/03/16 for units 1, 2, 4, 5, 6, 8, 9, 10, 12, 14, 15, 19 by Inspector Navarro; those separate cases will be referred to this case for management purposes. Previously condemned units 1, 2, 6, 8, and 12 were broken into and accessed without reinspection for occupancy. These units were secured again.. Roof inspection of both buildings showed west building in fair condition and east building in poor condition requiring repair; this roof had areas of uplift and depression with movement identified that may indicate dilapidated sheathing and should not be present in a roof in good repair. Inspected evaporative coolers for units 1, 2, 3, 8, 9, 19, 11, 12, 13, 18, 19, 20 (12 units); units 3, 8, 9, 10, 11, 12, and 20 were irreparably damaged by corrosion and rust inhibiting full and safe use; all units had electrical defects not to accepted code either by installation, subpanel securement, or lack of weatherproofing. Remaining units did not have coolers and have front installed A/C units. No one home at occupied units 11, 16, 17, or 18. Inspected unit 7; unit 20 declined. Note: occupants of unit 11 had left immediately upon our arrival. Unit 7 had incorrectly installed water heater, clogged sink, running toilet, and loose shower fixtures; holes in wall and broken window in kitchen; missing outlet and fixture covers. Accessed unoccupied units 1, 6, and 8 which showed continuing lack of electrical service, with ceiling and roof damage, clogged toilet and missing window in 8, missing water heater in 6. Multiple missing or broken windows prevalent in complex. Loose or incorrectly installed exterior lighting fixtures surrounding complex. Laundry room has incorrectly installed water heater with the venting terminating just below higher soffit of east building. Smoke detectors appear to be lacking or inoperable in all accessed units. Gas meters show many tagged for illegal use and others tagged as hazardous 9, 13, 17 (failed drop test?), 20 by SWG. Operable gas required for furnaces as installed for winter months.