Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/04/2016 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE, MET WITH TFD INVESTIGATORS, FIRE STARTED IN THE KITCHEN ABOVE THE CEILING. TFD FELT THE FIRE HAD BEEN SMOLDERING FOR SOME TIME AS THE FIRE STAYED SMALL AND CONTAINED TO A 6' X 8' AREA. rOOF STRUCTURE IS CONVENTIONAL FRAME, 2 X 8 RIDGE AND 2 X 6 RAFTERS OFF THE RIDGE. THE ROOF RAFTERS AND SHEATHING WAS NOT FIRE DAMAGED. THE CEILING WAS ALSO 2 X 6 CEILING JOISTS, 3 CEILING JOIST WERE BURNED THRU AND A 4 X 8 BEAM THAT THE SPANNED A PORTION OF THE KITCHEN WAS ALSO BURNED HALF WAY THRU >THERE WAS ELECTRICAL WIRING THAT WAS AFFECTED AND WIRING NOW EXPOSED. TEP CUT POWER AT THE SERVICE PANEL AND PINNED THE METER. PRESENTLY NO POWER. > 1/4" COPPER TUBING WAS ALSO MELTED, LOOKED LIKE IT RAN TO THE REFRIGERATOR. NOV WAS ISSUED FOR EMERGENCY VACATE DUE TO OWNER HAVING NO POWER, MR SCHICKLING STATED HW EOULD BE STAYING WITH FRIENDS. NOV, PERMITS REQUIRED WAS ALSO ISSUED WHILE ON SITE. |