Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/04/2016 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE, MET WITH TFD CAPTAIN, FIRE WAS ABOVE THE DROPPED CEILING OF THE 7-11. FOUND ELECTRICAL WIRING THAT RAN THRU THE FELX DUCT WORK UP TO THE ROOF. WHERE THE WIRING PENETRATED THRU THE DUCTWORK, THERE APPEARED TO BE A BARE SPOT IN THE WIRE AND HAD POSSIBLY BEEN ARCHING AND SMOLERING FOR SOME TIME AS FLAMES WERE MINIMAL BUT HAD BURNED THRU THE TWO TRUSSES ON EITHER SIDE OF THE DUCTWORK. DAMAGE IS AS FOLLOWS: >TWO OF THE TRUSSES EITHER SIDE OF THE DUCT WORK HAVE BEEN SEVERELY BURNED, BOTTOM CORD OF WEST TRUSS BURNED ALL THE WAY THROUGH. >FLEX DUCT, BOTH RETURN AIR, AND SUPPLY RECEIVED FIRE DAMAGE. >ELECTRICAL WIRING FIRE DAMAGED WHERE WIRING PENETRATED THE FLEX DUCT. FOUND WIRING RUNNING IN THE FLEX DUCT TO THE ROOF. |