Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2016 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL BY TFD: HOUSE FIRE THE FIRE STARTED IN THE SPARE BEDROOM. THE CEILING LIGHT FIXTURE WAS BURNT. THERE IS HEAT DAMAGE TO ALL THE WALL RECEPTACLES. THERE IS EXPOSED ROMEX IN THE CEILING AREA ALSO WITH HEAT DAMAGE. THE CEILING AND INTERIOR WALLS HAVE DRYWALL DAMAGE. THE INTERIOR DOOR WAS DAMAGED AND REMOVED. THERE IS A 4X4 ROOF CUT OUT AND THE 4X4 WINDOWS GLASS IS BROKEN. THE WINDOW DOES HAVE A GRATE SO NO NEED TO BOARD. THE HALLWAY LIGHT FIXTURE AND THERMOSTAT CONTROLLER MELTED. TEP DID PULL THE METER, THERE ALSO UNAPPROVED WIRING METHODS IN THE SPLIT BUS METER DISCONNECT, MULTIPLE CONDUCTORS ON ONE TERMINAL. SWG DID PIN THE GAS OFF. THE HOME WAS CONDEMNED UNSAFE TO OCCUPY, PLACARD POSTED. A NOTICE AND ORDER WAS POSTED. SCHEDULE A 60 DAYS FOLLOW INSPECTION FOR THE AREA INSPECTOR. |