Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T16DV00665
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/25/2016 | INSP - FOLLOW UP CODE ENFORCE | Approved | Met owner at pre-determined time at property, with Inspector Hollander. We examined the basement subpanel and explained what remained to be repaired, primarily an issue with the grounding and replacement of missing knockouts. Rechecked the smoke detectors, meets current placement requirements. Furnace repaired by licensed technican, have documentation. Water heater installation permit has been completed. | |
06/20/2016 | INSP - FOLLOW UP CODE ENFORCE | Approved | Tenant(s) finally agreed to allow inspection. Only 1 roomate available to meet or currently staying at property (but hold lease). New water heater installed in basement, but no permit on file. subpanel appears to have connectors installed for conduit, but does not appear to code and subpanel is missing blank covers; no permit on file or paperwork provided showing review by electrician; outlet missing cover (basement); all conduit seen in basement does not have a professional or good workmanship installation and is lacking permit. Ceiling fan in living room does not function. Smoke detector(s) not installed (tenant states owner provided but did not install; he can't find them now). Plumbing issues have been resolved. | |
02/08/2016 | INSP - FOLLOW UP CODE ENFORCE | Approved | Went to the property with inspector Rick Hollander and had no burning smell at the time of the inspection. The tenants had removed 2-outlets on the south wall in the living room where a supply vent had been covered and a box has been built to extend the supply air to the living room area. Did check the dinning room and they have done the same thing on that side. The box extending the area has wiring inside the boxed area with the 2-outlets where they have extended the exisiting outlet on the wall to the framed area building the box. The tenants are stating that the smoke was coming from the vent that supplies the air to the living and dinning room area and more from the living room area. The basement has new or added romex wiring with old wiring the is cut or not being used due has been replaced with new. They have J-boxes and sub-panels that do not have the property connectors needed at the entry into the boxes to hold the wiring in place or protect from getting damaged from sharp edges or being scraped. Have not been able to make contact with the owner and will be doing an N.O.V. RV. |