Permit: T16CM09708

Parcel: 114540640

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/06/2017 PLUMBING - ROUGH, SOIL Approved
02/03/2017 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1- SHALL PROVIDE A MINIMUM OF (2) PIPE SIZE DIAMETER FOR THE FLOOR SINK TRAP ARMS.
2- SHALL LOCATE THE HYDRO MECHANICAL GREASE INTERCEPTOR FLOW CONTROL AT THE INLET SIDE OF INTERCEPTOR.
3- SHALL PROVIDE A 4" DRAIN AT THE OUTLET OF GREASE INTERCEPTOR.
4- RETEST THE SYSTEM.
5- NOTE: OKAY TO BACKFILL TRENCHES EXCEPT THE BLDG. DRAINS TO THE GREASE INTERCEPTOR.
6- ELECTRICAL UNDERGROUND CONDUITS PROVIDED.