Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2017 | ELECTRIC - RECONNECT | Approved | ||
| 01/11/2017 | ELECTRIC - RECONNECT | Denied | 1-wiring not up to code, wire nuts/splice above cieling in hallway 2-damaged outlet at kitchen area 3-wiring cut off in walls 4-provide boxes at wire terminations 5-photos have been taken of hazardous conditions 6-consult qualified electrical contractor for repairs 7-see previous notes for additional corrections |
|
| 01/06/2017 | ELECTRIC - RECONNECT | Denied | POST ADDRESS VISIBLE FROM STREET SMOKE ALARM HALLWAY TERMINATE ROMEX IN KITCHEN INTO APPROVED BOX SERVICE PANEL NOT GROUNDED PROVIDE GROUND ROD SYSTEM DOUBLE LUGGED CIRCUITS WHITE 50 AMP HOT LEAD TO BE BLACK OR RED (TAPE OK) NOT INSTALLED TOCODE SECURE EXTERIOR CONDUIT ALL ADDITIONS SHOULD BE ON RECORD NOTES 1-7 FOR POWER |
|
| 12/30/2016 | ELECTRIC - RECONNECT | Denied | NO DEAD FRONT ON SERVICE PANEL KNOCK OUT PLUGS MISSING ON SERVICE PANEL BARE WIRES NEED TO BE CAPPED OFF NO SMOKE DETECTORS IN BEDROOMS OR HALLWAY BROKEN LIGHT SWITCH OUTLET COVERS MISSING |