Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T16CM09439
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/16/2017 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
02/15/2017 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
02/13/2017 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE A ELONGATED H.C. WATER CLOSET WITH AN OPEN FRONT SEAT AND THE FLUSH HANDLE LOCATED ON THE OPEN SIDE OF THE STALL. 2- SHALL PROVIDE AN APPROVED H.C. LAVATORY AND FAUCET WITH SINGLE HANDLES. 3- SHALL PROVIDE AN APPROVED WRAP PROTECTION FOR THE H.C. LAVATORY WASTE AND WATER SUPPLYS. 4- INSTALL THE GRAB BARS AS PER THE APPROVED DETAIL ON THE PLAN. 5- SHALL PROVIDE AN EXPANSION TANK FOR THE WATER HEATER. 6- SHALL PROVIDE EXIT AND ACCESSIBILITY SIGNS FOR RESTROOM, FRONTAND REAR EXIT AND AT THE HALLWAY DOOR. 7- SHALL PROVIDE INDIRECT WASTE LINES FOR EACH COMPARTMENTS AND TERMINATE TO THE FLOOR SINK WITH AN AIR GAP. 8- REMOVE ALL METAL BOXES RECEPTICAL COVER PLATES FOR GROUND VERIFICATION. 9- SHALL PROVIDE THE REQUIRED DOOR HARDWARE HANDLES AS PER THE APPROVED DRAWINGS FOR THE RESTROOM DOOR. 10- SHALL PROVIDE TOWEL, TOILET PAPER DISPENSER AND MIRROR AS PER THE APPROVED DETAILS ON THE PLAN. * |