Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/02/2019 |
MECHANICAL - INTERMEDIATE |
|
Approved |
|
| 05/04/2018 |
MECHANICAL - INTERMEDIATE |
|
Cancelled |
IVRS - AP canceled |
| 03/05/2018 |
MECHANICAL - INTERMEDIATE |
|
Approved |
|
| 03/05/2018 |
MECHANICAL - INTERMEDIATE |
|
Denied |
1 provide engineering on a1 truss repair 2 seal oll top plate penetrations 3 cripple a/c vents 4 shim bearing headers 5 provide attic access 6provide min 10' dwv test 7 provide min 12" from can lights to pex |