Permit: T16CM08867

Parcel: 13309060D


Addresses:

7901 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/14/2017 PLUMBING - FINAL Approved IVRS - Inspection :*
02/13/2017 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1- SHALL LOCATE THE REAR WATER CLOSET GRAB BAR IN THE WOMENS RESTROOM 12" TO THE CENTER OF WATER CLOSET.
2- SHALL PROVIDE PROTECTION WRAP FOR THE H.C. LAVATORYS WASTE AND WATER SUPPLYS.
3- SHALL PROVIDE 10 SECONDS OF FLOW FOR THE H.C. LAVATORY FAUCET.
4- MENS H.C. WATER CLOSET SHALL BE LOCATED 16" TO 18" MAX OF SIDE WALL CLEARANCE.
02/09/2017 PLUMBING - FINAL Not ready for Inspection NOT READY