Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T16CM08867

Parcel: 13309060D


Addresses:

7901 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T16CM08867

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/14/2017 PLUMBING - FINAL Approved IVRS - Inspection :*
02/13/2017 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1- SHALL LOCATE THE REAR WATER CLOSET GRAB BAR IN THE WOMENS RESTROOM 12" TO THE CENTER OF WATER CLOSET.
2- SHALL PROVIDE PROTECTION WRAP FOR THE H.C. LAVATORYS WASTE AND WATER SUPPLYS.
3- SHALL PROVIDE 10 SECONDS OF FLOW FOR THE H.C. LAVATORY FAUCET.
4- MENS H.C. WATER CLOSET SHALL BE LOCATED 16" TO 18" MAX OF SIDE WALL CLEARANCE.
02/09/2017 PLUMBING - FINAL Not ready for Inspection NOT READY