643 N CATALINA AV

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
06/07/2017 ELECTRIC - INTERMEDIATE Approved
06/05/2017 ELECTRIC - INTERMEDIATE Denied 1- SHALL REMOVE THE 2" SAN CROSS AT THE A W DRAIN AND PROVIDE A SAN TYEE AND LOCATE THE CLEAN OUT ABOVE THE KITCHEN WET VENTED SECTION AND TRAP ARM.
2- SHALL REMOVE AND REPLACE THE 2" x 11/2" FERNCO COUPLING AT THE TUB TRAP ARM AND PROVIDE AN MISSION SPECIALTY COUPLING.
3- SHALL SEAL ALL TOP PLATE PENETRATIONS WITH FIRE RATED CAULKING OR FOAM.