Permit: T16CM08809

Parcel: 122090540


Addresses:

4026 E JUSTIN LN

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
01/09/2017 ELECTRIC - INTERMEDIATE Approved
01/04/2017 ELECTRIC - INTERMEDIATE Denied 1- SHALL PROVIDE A GROUND TAIL FOR ALL METAL RECEPTICAL BOXES.
2- SHALL REPLACE THE DAMAGED ROMEX IN WALL LOCATED IN THE MASTER BEDROOM.
3-SHALL PROVIDE MISSION SPECIALTY OUPLINGS ON DWV SYSTEM WHEN CONNECTING DISSIMULAR MATERIALS.
4- SHALL PROVIDE A SANITARY TEE FOR THE TRAP ARM IN THE MAIN BATHROOM.
5- SHALL PROVIDE THE PROPER CONNECTION FOR THE WATER LINES IN THE PLUMBING WALL WHEN CONNECTING TO DISSIMULAR MATERIAL..