Permit: T16CM08610

Parcel: 103175020


Addresses:

3029 N GAIA PL

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
01/11/2017 BUILDING - FINAL Approved APPROVED
01/06/2017 BUILDING - FINAL Denied MISSING BOND BUSHING ON LOWER SOLAR CONDUIT
MISSING WIRE CLAMP ON GEC AT SERVICE PANEL
NEW SERVICE PANEL IS NOW A MAIN PANEL, NEUTRAL AND GROUND MUST BE BONDED TOGETHER.
OLD SERVICE PANEL IN HOME IS NOW A SUB-PANEL, UN-BOND NEUTRAL AND GROUND.
01/03/2017 BUILDING - FINAL Denied MISSING GROUND ROD
MISSING BOND BUSHING ON LOWER CONDUIT
#3/0 NEUTRAL WIRE IS NOT LANDED
PLASTIC AT THE BREAKER LUG IS BROKEN.
END INSPECTION
12/30/2016 BUILDING - FINAL Not ready for Inspection