Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T16CM08564
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/24/2018 | REINFORCED MASONRY PRE-GROUT | Approved | ||
09/27/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | MAINTENANCE BUILDING TOP OF WALL OK | |
09/22/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SEE TERRACON REPORT ATTACHED | |
09/13/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | MAINTENANCE BUILDING OK TO 4'. WEST KENNEL OK TO 10'8" AND 12'6". DOG ADOPTION OK TO 10'8". | |
09/07/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BUILDING C WEST OK TO 4' BUILDING B OK TO TOP OF WALL |
|
09/01/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BUILDINGS: EAST KENNEL AND MEDICAL APPROVED TO GROUT TO 13'6" (SEE DETAILS IN TERRACON REPORT) | |
08/24/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BUILDING C ROOMS 3005 AND 3006 OK TO TOW ROOM 5016 OK TO TOW ROOM 5101 OK TO 4' |
|
08/22/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SEE TERRACON REPORT ATTACHED | |
08/18/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
08/14/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BUILDING C EAST STRAY DOG, TOP OUT HIGH CENTER SECTION BUILDING B 2C 2D TO 2.2 2.4 BUILDING D 3A 3.1 TO 3.3, 4' TO 8' 2NDLIFT |
|
08/10/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BUILDING C OK TO TOW BUILDING D OK TO 4' |
|
08/08/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BUILDING B OK TO 8' BUILDING C OK TO 12' | |
08/04/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CAT SUN PORCH OK TO GROUT TO TOW | |
08/02/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | PER TERRACON REPORT | |
07/28/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | NORTH LINTEL AT ADMIN OK TO GROUT, EAST KENNEL OK TO 4' | |
07/26/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | EAST AND WEST KENNELS OK TO 8' | |
07/19/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ADMINISTRATION, AND KENNEL OK TO TOP OF WALL | |
07/14/2017 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | RAINED - OUT. CONTRACTOR CANCELLED. WILL RESCHEDULE FOR 17 JULY 2017. | |
07/11/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ADMIN BLD. 10' TO 12' OK TO GROUT. | |
06/29/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ADMIN EAST OK TO 12' | |
06/23/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ADMIN EAST OK TO GROUT TO 8' | |
06/14/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ADMIN. BLD. NORTH, WEST,SOUTH AND INTERIOR WALLS OK TO 4' (GL 1.8 TO 1.15 / 1.B TO 1.L) | |
06/05/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BUILDING "A" - GL: 1.1 - 1.8/1.H - 1.L; FIRST LIFT. OK TO GROUT PROGRRESS AREAS. | |
04/14/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SITE WALL FROM BEGINNING OF MH2 ZONING SOUTH 260' |