Permit: T16CM08449

Parcel: 133244550


Addresses:

851 N ROBB HILL PL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T16CM08449

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/07/2017 PLUMBING - INTERMEDIATE Approved
03/06/2017 PLUMBING - INTERMEDIATE Denied 1- THE VENT FOR THE 2ND FLOOR TUB SHALL RISE VERTICAL TO 6" ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE BEFORE IS CAN RUN HORIZONTAL. REFERENCE SECTION P3104.4 2012 IPC.
2- RETEST THE SYSTEM.
03/03/2017 PLUMBING - INTERMEDIATE Denied SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM.
2- SHALL PROVIDE A VENT FOR THE 2ND FLOOR TUB WASTE LINE.
03/02/2017 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM.
2- SHALL STRAP DOWN THE PEX WATER LINES EVERY 32" HORIZONTALY.


*