Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T16CM08449
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2017 | PLUMBING - INTERMEDIATE | Approved | ||
03/06/2017 | PLUMBING - INTERMEDIATE | Denied | 1- THE VENT FOR THE 2ND FLOOR TUB SHALL RISE VERTICAL TO 6" ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE BEFORE IS CAN RUN HORIZONTAL. REFERENCE SECTION P3104.4 2012 IPC. 2- RETEST THE SYSTEM. |
|
03/03/2017 | PLUMBING - INTERMEDIATE | Denied | SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM. 2- SHALL PROVIDE A VENT FOR THE 2ND FLOOR TUB WASTE LINE. |
|
03/02/2017 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM. 2- SHALL STRAP DOWN THE PEX WATER LINES EVERY 32" HORIZONTALY. * |