Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/04/2016 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/02/2016 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999

1- SHALL PROVIDE THE REQUIRED TEST GAGE OF 15 LBS. MAX WITH 1/10TH INCREMENTS FOR THE AIR PRESSURE TEST.

2- SHALL PROVIDE A 1" CLEARANCE AROUND COMBUSTIONABLE MATERIAL FOR THE WATER HEATER DBL. WALL FLU VENT THRU ROOF.

3- SHALL PROVIDE DBL. WALL FLU VENT FOR THE WATER ALL THE WAY TO THE DRAFT COLLAR. SINGLE WALL FLU VENT IS NOT APPROVED IN A EXTERIOR LOCATION.

5- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR LOCATED NEAR THE GAS RANGE.


*