Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2017 | ELECTRIC - RECONNECT | Approved | OK RES. RECN | |
| 01/10/2017 | ELECTRIC - RECONNECT | Denied | PROVIDE CIRCUIT BREAKER BLANK COVERS AT PANEL BOX. PROVIDE ROMEX WIRE CONNECTOR ON FLOOD LIGHTS AT CARPORT. |
|
| 10/25/2016 | ELECTRIC - RECONNECT | Denied | REMOVE 3 CIRCUITS WITH EXPOSED ROMEX WIRING COMING OUT OF TOP OF PANEL AND REMOVE ALL WIRING AND FIXTURE RELATED TO THESE CIRCUITS OR WIRE TO CODE. SEAL HOLES IN TOP OF PANEL. PROVIDE BLANKOFFS WHERE BREAKERS ARE MISSING IN PANEL. REMOVE THE 2 FRONT PORCH LIGHTS OR WIRE TO CODE. PROVIDE ROMEX CONNECTORS AT 2 FLOOD LIGHTS IN CARPORT. RELOCATE BEDROOM SMOKE DETECTORS. MIN. 3' FROM AIR VENTS AND TO WITHIN 12" OF CEILING. DETECTOR IS MISSING IN ONE BEDROOM. |