Permit: T16CM07984

Parcel: 122183920


Addresses:

3544 E WILLARD ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/31/2016 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
10/27/2016 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999

1- THE AIR PRESSURE TEST GAGE WAS AT 2 PSI AT THE TIME OF INSPECTION, CHECK THE SYSTEM FOR LEAKS.


*
10/21/2016 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999

1- GAS GAGE FOR THE AIR PRESSURE TEST IS NOT WORKING.

2- WATER HEATER T & p DRAIN SHALL BE EXTENDED AND TERMINATE 6" A.F.F.

3- SHALL PROVIDE DOUBLE WALL FLU VENT FOR THE WATER HEATER AND SHALL EXTEND A MINIMUM OF 1" THRU THE CEILING AND SHALL BE A MINIMUM OF 5' 0" IN LENGTH.

4- PROVIDE (3) SHEET METAL SCREWS PER JOINT ON VENT CONNECTOR.

5- SHALL PROVIDE A CRBON MONOXCIDE DETECTOR.


*