Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2016 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/28/2016 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 10/21/2016 | PLUMBING - FINAL | Not ready for Inspection | 1- this is a new installation, currently all appliances are elec., provide correct description of work on permit 2-at least one appliance must be installed to clear gas. 3-permits required when converting water heater and furnace to gas from elec. 4-flue piping to be installed and inspected prior to gas clearence. 5-no clearence given at this time |