Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T16CM07452

Parcel: 13711539E


Addresses:

5160 S RIVER RUN DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/15/2016 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/10/2016 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
11/09/2016 EXT METAL CLIPS/EXT SHEATHING Partial Approval MISSING SP-4 CLIP SW CORNER
STRAP TOP PLATES AT FRONT PORCH NE CORNER
CLIP H02 & H03 3PT BEARING TRUSSES
DOUBLE STUD H02 DOUBLE GIRDDER TRUSS
CLIP CG01 TRUSSES