Permit: T16CM07052

Parcel: 111031120

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/29/2017 BUILDING - FINAL Approved APPROVED
02/28/2017 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- A WATER FLEX CONNECTOR IS NOT ALLOWED ON THE T & P DRAIN AND HAS BACK PITCH.
2- THE LIQUID TIGHT ELECTRIC WHIP IS NOT SECURED.


*
02/22/2017 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE CPVC MATERIAL FOR THE WATER HEATER T & P DRAIN.
2- THE WATER HEATER T & P DRAIN SHALL NOT HAVE TRAPPED WATER IN THE LINE AT THE VALVE.
3- SECURE THE LIQUID TIGHT AT THE WATER HEATER DISCONNECT.

*