Inspection History: ELECTRIC - RECONNECT

Permit Number - T16CM06885

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
09/22/2016 ELECTRIC - RECONNECT Approved
09/15/2016 ELECTRIC - RECONNECT Partial Approval 3/6 ITEMS ABATED.
REMAINING: INTERIOR AND ESTERIOR PANEL BREAKER LABELS, AND MISSING GROUND RODS AT THE MAIN PANEL.
09/08/2016 ELECTRIC - RECONNECT Denied NO GFCI AT KITCHEN,
INTERIOR PANEL- BREAKERS NOT LABELED,
EXTERIOR PANEL- BREAKERS NOT LABELED,
DINING ROOM SWITCH COVER TAPED CLOSED AND PAINTED OVER TO CONCEAL,
NO GAS BOND FOUND,
EXPOSE UFER OR GROUND RODS AT MAIN PANEL.