Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T16CM06538
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2017 | PLUMBING - INTERMEDIATE | Approved | ||
| 09/12/2017 | PLUMBING - INTERMEDIATE | Partial Approval | TUB FILL TEST OK. NAIL PROTECTION AND FIRE STOPPING INCOMPLETE | |
| 09/08/2017 | PLUMBING - INTERMEDIATE | Partial Approval | FIRST FLOOR BUILDING A EAST OF HALLWAY ONLY | |
| 09/05/2017 | PLUMBING - INTERMEDIATE | Partial Approval | WATER LINES IN AREA 'B' OK | |
| 08/25/2017 | PLUMBING - INTERMEDIATE | Partial Approval | AREA "B" DWV OK. | |
| 08/18/2017 | PLUMBING - INTERMEDIATE | Partial Approval | BUILDING A ALL THREE FLOORS DWV OK | |
| 08/15/2017 | PLUMBING - INTERMEDIATE | Partial Approval | WATER LINES IN SECTION A OK REPAIR DWV VENTS THAT HAVE HORIZONTAL BELOW 48" AND RE-TEST. NOTE: NAIL PROTECTION (BANG PLATES) MUST EXTEND 2" ABOVE SOLE PLATE, AND 2" BELOW TOP PLATE. |
|
| 08/14/2017 | PLUMBING - INTERMEDIATE | Partial Approval | THIRD FLOOR EAST OF HALLWAY OK DWV OK. WEST OF HALLWAY, ALL THREE FLOORS, NORTH OF SECTION B OK. |
|
| 08/11/2017 | PLUMBING - INTERMEDIATE | Cancelled | IVRS - RI canceled | |
| 08/09/2017 | PLUMBING - INTERMEDIATE | Not ready for Inspection | CONTRACTOR CANCELLED - WASTE LINE DAMAGED; REPLACED. WILL RESCHEDULE INSPECTION. | |
| 05/12/2017 | PLUMBING - INTERMEDIATE | Partial Approval | DWV WASTE TEST ONLY 1ST FLOOR UNITS 101,102,103 & 104 1ST FLOOR ONLY NAIL PROTECTION NEED THROUGH OUT SEAL ALL TOP PLATE PENETRATIONS |