Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2016 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/23/2016 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE A SAFTEY PROTECTION PLATE THAT EXTENDS 2" BELOW THE TOP PLATE AT WAHER VENT. 2- SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM TO THE TOP OF VENT. 2- SHALL PROVIDE A SEDIMENT TRAP AT THE WATER HEATER GAS SUPPLY. 4- SHALL REMOVE THE SANITARY TEE THAT IS POSITIONED ON ITS BACK FOR THE VENT TO THE WASHER BOX AND PROVIDE A DIRECTIONAL FITTING. * |
|
| 08/12/2016 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* |