| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2017 | FRAMING | Approved | ||
| 09/16/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/14/2016 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999 * |
|
| 09/14/2016 | FRAMING | Denied | FIRE BLOCK DROPPED CEILINGS OVERSPAN DROPPED CEILINGS COMPLETE POWDER ROOM DOOR FRAME COMPLETE LIVING ROOM LID SECURE ROMEX 8" FROM BOXES EXCEPT POTABLE WATER TO FRIDGE SECURE HOME RUNS AT SUBPANEL NAIL PROTECT PLUMBING THROUGHTOUT WATER CLOSET REQUIRES 12" CLEARANCE ON SIDES BEDROOM WINDOWS DO NOT MEET EGRESS REQUIREMENTS 5.7 SQ FT EXCEPT FRONT PORCH |
|
| 09/12/2016 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999 no fire blocking and framing is not complete is master bedroom * |