Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T16CM03843
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/19/2016 | FRAMING | Approved | IVRS - Inspection :* | |
08/18/2016 | FRAMING | Partial Approval | METAL J HOOKS NOT APPROVEDFOR SUPPORTING PVC. PLUMBERS TAPE NOT APPROVED FOR SECURING DWV. DWV NOT UNDER TEST. FOIL TAPE NOT APPROVED FOR SECURING LINE SET. NYLON STRAPPING ONLY APPROVED FOR FLEX DUCT. PROVIDE BACKING AT CEILING BOXES. REMOVE WATER HEATER PLATFORM TO SEE DRAINS ON TUB. UFER NOT TERMINATED CORRECTLY. 15 PSI TEST ON GAS LINE OK. |