Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T16CM03461
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2017 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
02/13/2017 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE A 25 AMP FUSE FOR THE AC CONDENSOR UNIT. 2- SHALL SEAL DRINKING FOUNTAIN AT WALL. 3- SHALL INSTALL SIDE WALL GRAB BARS 12" CENTER FROM REAR WALL AT LOWER LEVEL. 4- SHALL LOCATE MIRROW AT 40" A.F.F AT LOWER LEVEL RESTROOMS. 5- SHALL LOWER THE TOWEL DISPENSERS IN THE MENS AND WOMENS RESTROOMS LOWER LEVEL. 6- LOWER LEVEL HOSE BIB MISSING. 7- LOWER LEVEL MENS AND WOMENS WATER CLOSETS SHALL BE 16" TO 18" SIDE WALL CLEARANCE. 8- SHALL PROVIDE HEAT TRAPS AT WATER CLOSETS. * |