Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2016 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 08/25/2016 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE AN APPROVED STRAP FOR THE DISHWASHER DISCHARGE DRAIN HOSE AS HIGH AS POSSIBLE TO THE COUNTER TOP. 2- SHALL PROVIDE A SEDIMENT TRAP FOR THE WATER HEATER. 3- SHALL PROVIDE A VACUUM BREAKER AT FRONT AND REAR HOSE BIBS. 4- SHALL PAINT THE CONDENSATE DRAIN FOR PROTECTION. 5- PROVIDE ACCESS TO THE ROOF AT TIME OF INSPECTION. 6- PROVIDE CAULKING FOR THE WATER CLOSETS. 7- SHALL PROVIDE A STRAP FOR THE LIQUID TIGHT ELECTRICAL WHIP AT THE AC UNIT ON ROOF. * |