Permit: T16CM02755

Parcel: 141401770

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T16CM02755

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/18/2016 FRAMING Approved IVRS - Inspection :*
07/15/2016 FRAMING Not ready for Inspection INSP CANCELLED

SUPPORT FLEX DUCT.
SUPPORT DRYER VENTS W/ APPROVED STRAPPING. RIVIT JOINTS.
FLEX DUCT STRAPPING IS NOT APPROVED FOR LINE SET PIPING.
SECURE AND SUPPORT PEX PER INSTALL INSTR. NOT TO EXCEED 32" OC
ISOLATE PEX FROM GANG NAILERS
SECURE FIRST FLOOR CLOSET FLANGES TO CONCRETE, WILL ALLOW CORROSION RESISTANT CONCRETE ANCHORS
SECURE 2ND STORY CLOSET FLANGES WITH CORROSION RESISTANT SCREWS EQUALL TO BRASS. P2705.1 INSTALL AT FINISHED FLOOR ELEVATION OR PROVIDE INSTALLATION INSTRUCTIONS FOR INSPECTOR REVIEW.
SUPPORT AND SECURE GAS PIPING AT FIRE PL AND OVERHEAD.
PROVIDE A LATTER FOR FAU INSPT ABV CEILING.