Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T16CM02480
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2017 | PLUMBING - INTERMEDIATE | Approved | ||
| 06/30/2017 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1- NOT READY FOR INSPECTION . | |
| 05/18/2017 | PLUMBING - INTERMEDIATE | Partial Approval | 1- DWV WATER TEST PROVIDED. 2- OVERHEAD AND IN WALL DOMESTIC WATER DISTRIBUTION IS OKAY IN BLDG C-4 AREA ONLY. |
|
| 05/16/2017 | PLUMBING - INTERMEDIATE | Not ready for Inspection | ||
| 05/12/2017 | PLUMBING - INTERMEDIATE | Partial Approval | 1- BLDG.C-3 CORRIDOR AND PATIENT ROOMS C-3 AND C-4 HVAC DUCT IS OKAY. 2- HVAC DUCT & FIREPLACE AND HIGH CEILING IS OKAY 3-GREASE HOOD EXHAUST DUCT INSTALLATION OKAY, SMOKE TEST TO BE PERFORMED AT A LATER TIME. 4- BLDG. C-3 AND C-4 ELECTRIC IN WALLS AND ABOVE CEILING IS OKAY. 5- MED GAS PRESSURE TEST PROVIDED. IN C-3 & C-4. 6- DWV WATER TEST PROVIDED IN C-3. 7- OVERHEAD AND IN WALL DOMESTIC WATER DISTRIBUTION IS OKAY IN C-3. |
|
| 04/25/2017 | PLUMBING - INTERMEDIATE | Partial Approval | 1- DWV WATER TEST PROVIDED IN BLDG. (C) NORTH. 2- OVERHEAD AND IN WALL DOMECTIC WATER DISTRIBUTION IS OKAY IN BLDG. (C) NORTH. 3- BOND BEAM PROVIDED FOR THE MASONARY LAST LIFT FOR THE TRASH ENCLOSURE. |
|
| 04/20/2017 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1- NOT READY FOR INSPECTION. | |
| 04/19/2017 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1- NOT READY FOR INSPECTION. | |
| 04/12/2017 | PLUMBING - INTERMEDIATE | Partial Approval | 1- DWV WATER TEST PROVIDED. 2- IN WALL DOMESTIC WATER DISTRIBUTION IS OKAY. 3- THIS INSPECTION IS FOR BLDG. (C)-1 SOUTH ONLY. |
|
| 03/24/2017 | PLUMBING - INTERMEDIATE | Partial Approval | 1- DWV WATER TEST PROVIDED. 2- OVERHEAD AND IN WALL DOMESTIC WATER DISTRIBUTION IS OKAY. 3- THIS INSPECTION IS FOR BLDG. (B) SOUTH ONLY. |
|
| 03/15/2017 | PLUMBING - INTERMEDIATE | Partial Approval | 1- KITCHEN GAS PRESSURE TEST PROVIDED FOR DROPS AND IN WALL PIPING. 2- DWV WATER TEST IN KITCHEN WALLS ONLY PROVIDED |
|
| 03/06/2017 | PLUMBING - INTERMEDIATE | Partial Approval | 1- DWV WATER TEST PROVIDED. 2- DOMESTIC WATER DISTRIBUTION OVERHEAD AND IN WALL IS OKAY. 3- THIS INSPECTION IS FOR BLDG. (A)-4 |
|
| 03/01/2017 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1- DWV WATER TEST PROVIDED IN BLDG. (A) 3. 2- DOMESTIC WATER DISTRIBUTION OVERHEAD AND IN WALSS ARE OKAY. |
|
| 02/24/2017 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 02/22/2017 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1- DWV WATER TEST PROVIDED. 2- OVERHEAD AND IN WALL DOMESTIC WATER DISTRIBUTION IS OKAY. 3- THIS INSPECTION IS FOR BLDG. A NORTH ONLY. |