Permit: T16CM01914

Parcel: 11011174J


Addresses:

2480 N ARCADIA AV

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
10/02/2017 REINFORCED MASONRY PRE-GROUT Approved
05/23/2017 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT AND TOP OFF MECH. YARD WALL.
05/16/2017 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT MECH. YARD WALL TO 12'.
05/10/2017 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT MECH. YARD WALL TO 8'
05/04/2017 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT MECH. YARD WALL TO 5'4"
01/06/2017 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT ELEVATOR SHAFT AND TOP OFF.
01/05/2017 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT NORTH STAIRWELL TO 32'
01/04/2017 REINFORCED MASONRY PRE-GROUT Partial Approval
12/29/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT SOUTH STAIRWELL TO 29'4"
12/27/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT ALL 3 AREAS TO 25'4".
12/21/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT NORTH STAIRWELL TO 21'4" AND ELEVATOR SHAFT TO 17'4"
12/20/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT SOUTH STAIRWELL TO 21'4" AND ELEVATOR SHAFT TO 13'4"
12/16/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 1- NORTH STAIRWELL MASONARY LIFT 17-4 ABOVE 100 IS OKAY FOR GROUT.
12/13/2016 REINFORCED MASONRY PRE-GROUT Partial Approval 1- NORTH STAIRWELL MASONARY LIFT IS 13-4 ABOVE 100
12/12/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT SOUTH STAIRWELL TO 13'4" ABOVE 100 AND ELEVATOR TO 9'4" ABOVE 100.
12/09/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT NORTH AND SOUTH STAIRWELLS TO 20' AND ELEVATOR SHAFT TO 5' ABOVE 100.
12/06/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT NORTH AND SOUTH STAIRWELLS TO 9'4" AND ELEVATOR SHAFT TO 16'.
CONFIRMED 3 GROUND RODS FOR LIGHTNING PROTECTION.
12/02/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT NORTH AND SOUTH STAIRWELLS TO 5'4" ABOVE 100.
11/30/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT NORTH AND SOUTH STAIRWELLS UP TO 16' AND ELEVATOR SHAFT TO 16'
11/29/2016 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
11/28/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT NORTH AND SOUTH STAIRWELLS TO 12'.
11/03/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT TO 8' AT SOUTH STAIRWELL.
11/01/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT 22" TO 48" LIFT AT SOUTH STAIRWELL.
10/31/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT STEM WALL 0-22" AT SOUTH STAIRWELL.
10/26/2016 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT NEXT 8'-11'4" LIFT AT NORTH STAIRWELL.
OK TO GROUT NEXT 4'-8' LIFT AT ELEVATOR.
10/25/2016 REINFORCED MASONRY PRE-GROUT Partial Approval
10/24/2016 REINFORCED MASONRY PRE-GROUT Partial Approval
10/21/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*