Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T15OT01177

Parcel: 12201024H


Addresses:

3904 E GRANT RD


Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T15OT01177

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
09/28/2015 SIGN SITE REVIEW Approved PERMIT READY TO PAY FOR & PICK UP
09/04/2015 SIGN SITE REVIEW Denied IORA
T15OT01177
REVSION: NA/ORGINAL
RECEIVED: 8/29/15
REVIEWED: 9/4/15 by Sign Permit Team
APPLICATION & DRAWING DENIED. A revision is required as per Sign Code 3-16.
Revisions required include...
Page 1 of the drawings submitted must be marked with an (A).
All of the information on the application that pertains to SIGN (A) must also be on Page 1 (A) of the drawing.
The information required on Page 1 (A) of the drawing includes
1.A scaled image of SIGN (A) showing its
a. width & length in "decimal feet" (ex. 3.58') to match application.
b. the square footage in "decimal feet" (ex. 24.17 SQ FT) to match application.
c. the scale used (ex. SCALE 3/8"=1')
2. A photo of the building elevation showing the placement of SIGN (A) to scale, showing the
a."Over all height" of the top of SIGN (A) in "decimal feet" (ex. OAH 19') to match application.
b.Frontage of the building/suite in "decimal feet" (ex. 67') to match application.
c.Direction that the elevation faces (ex. NORTH ELEVATION)
d.the scale used (ex. SCALE 1/4"=1')
3.A construction/electrical diagram of SIGN (A) showing
a.Construction details
b.Attachment details (number, size and type of anchors)
c.Materials used in construction of the wall. (ex. Masonry wall)
d.Type of illumination (ex. LED)
e.Indicate the AMPS__ VOLTS__ CIRCUITS__
f.Include the following note " 24 Hour programmable timer installed
to comply with the COT outdoor lighting code"
4.Each page must show
a. Title bar of installer applying for the permit (ex. Global Sign Works)
b.Must note page number and number of pages submitted. (ex. Page 1 of 2)

Page 2 of the drawings submitted must be marked LOCATION MAP
1. The last page of the submitted packet must be the LOCATION MAP showing
a. A map of the existing site. (a Google aerial photo is good)
b. Clearly label all adjacent streets
c. The location of sign A on the correct building elevation with arrow.
d. Show frontage 81'to match application on map
e. Must note page number and number of pages submitted. (ex. Page 2 of 2)