Permit Number - T15OT01099

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
09/09/2015 SIGN SITE REVIEW Approved PERMIT READY TO PAY FOR & PICK UP
08/25/2015 SIGN SITE REVIEW Correction Required DENNYS
T15OT01099
REVSION: NA/ORGINAL
RECEIVED: 8/18/15
REVIEWED: 8/25/15 by Sign Permit Team

APPLICATION & DRAWING DENIED. A revision is required as per Sign Code 3-16.
Revisions required include...

Page 1 of the drawings submitted must be marked with an (A).
All of the information on the application that pertains to SIGN (A) must also be on Page 1 (A) of the drawing.
The information required on Page 1 (A) of the drawing includes
1.A scaled image of SIGN (A) showing its
a.width & length in "decimal feet" (ex. 3.58')
2.A photo of the building elevation showing the placement of SIGN (A) to scale, showing the..
a."Over all height" of the top of SIGN (A) in "decimal feet" (ex. OAH 16.75')
b.the scale used (ex. SCALE 1/4"=1')
3.A construction/electrical diagram of SIGN (A) showing
a.Construction details
b.Attachment details (number, size and type of anchors)
c.Materials used in construction of the wall. (ex. Masonry wall)
d.Show an illustration of & label the DISCONNECT SWITCH
e.Include the following note " 24 Hour programmable timer installed
to comply with the COT outdoor lighting code"
4.Each page must show
a. Must note page number and number of pages submitted. (ex. Page 1 of 4)
Page 2 of the drawings submitted must be marked with an (B).
All of the information on the application that pertains to SIGN (B) must also be on Page 2 (B) of the drawing.
The information required on Page 2 (B) of the drawing includes
1.A scaled image of SIGN (B) showing its
a.width & length in "decimal feet" (ex. 3.58')
2.A photo of the building elevation showing the placement of SIGN (B) to scale, showing the
a."Over all height" of the top of SIGN (B) in "decimal feet" (ex. OAH 16.75')
b.the scale used (ex. SCALE 1/4"=1')
3.A construction/electrical diagram of SIGN (B) showing
a.Construction details
b.Attachment details (number, size and type of anchors)
c.Materials used in construction of the wall. (ex. Masonry wall)
d.Show an illustration of & label the DISCONNECT SWITCH
e.Include the following note " 24 Hour programmable timer installed
to comply with the COT outdoor lighting code"
4.Each page must show
a. Must note page number and number of pages submitted. (ex. Page 2 of 4)

Page 3 of the drawings submitted must be marked with an (C).
All of the information on the application that pertains to SIGN (C) must also be on Page 3(C) of the drawing.
The information required on Page 3(C) of the drawing includes
1.A scaled image of SIGN (C showing its
a.width & length in "decimal feet" (ex. 3.58')
2.A photo of the building elevation showing the placement of SIGN (C) to scale, showing the
a."Over all height" of the top of SIGN (C) in "decimal feet" (ex. OAH 16.75')
b.the scale used (ex. SCALE 1/4"=1')
3.A construction/electrical diagram of SIGN (C) showing
a.Construction details
b.Attachment details (number, size and type of anchors)
c.Materials used in construction of the wall. (ex. Masonry wall)
d.Show an illustration of & label the DISCONNECT SWITCH
e.Include the following note " 24 Hour programmable timer installed
to comply with the COT outdoor lighting code"
4.Each page must show
a. Must note page number and number of pages submitted. (ex. Page 3 of 4)

Page 4 of the drawings submitted must be marked LOCATION MAP
1. The last page of the submitted packet must be the LOCATION MAP showing
a. A map of the existing site. (a Google aerial photo is good)
b. Clearly label all adjacent streets
c. A "north directional arrow"
d. The location of all signs (A,B,C) on the correct building elevations with arrows.
e. Must note page number and number of pages submitted. (ex. Page 4 of 4)