Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SITE REVIEW
Permit Number - T15OT01007
Inspection Description - SIGN SITE REVIEW
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2015 | SIGN SITE REVIEW | Approved | PERMIT READY TO PAY FOR & PICK UP | |
08/07/2015 | SIGN SITE REVIEW | Denied | ANDYS AMERICAN GLASS T15OT01007 REVSION: NA/ORGINAL RECEIVED: 7/31/15 REVIEWED: 8/7/15 by Sign Permit Team APPLICATION & DRAWING DENIED. A revision is required as per Sign Code 3-16. Revisions required include: 1.Application: a.Fill in box requesting "where annual bill is to be mailed" b.Change "SIGN TYPE" of SIGN C from monument to "C of C" 2.Drawings: Page 1: The information required on Page 1 (A) of the drawing includes a.Label Page 1 "SIGN (A)" b.Cabinet width & length in "decimal feet" (ex. 3.58') to match application. c.the square footage in "decimal feet" (ex. 55 SQ FT) d.the scale used (ex. SCALE 3/8"=1') e.OAH (over all height of sign) f.Include the following note " 24 Hour programmable times installed to comply with the COT outdoor lighting code" g.Must note page number and number of pages submitted. (ex. Page 1 of 4) h.Elevation photo must include the following i."Over all height" of the top of SIGN (A) in "decimal feet" (ex. OAH 16. 5') ii.Frontage of the building/suite in "decimal feet" (ex. 25') iii.Direction that the elevation faces (ex. NORTH ELEVATION) iv.the scale used (ex. SCALE 1/4"=1') Page 2: The information required on Page 2 (B) of the drawing includes a.Label Page 1 "SIGN (B)" b.Cabinet width & length in "decimal feet" (ex. 3.58') to match application. c.the square footage in "decimal feet" (ex. 55 SQ FT) d.the scale used (ex. SCALE 3/8"=1') e.OAH (over all height of sign) f.Include the following note " 24 Hour programmable times installed to comply with the COT outdoor lighting code" g.Must note page number and number of pages submitted. (ex. Page 2 of 4) h.Elevation photo must include the following v."Over all height" of the top of SIGN (B) in "decimal feet" (ex. OAH 16. 5') vi.Frontage of the building/suite in "decimal feet" (ex. 25') vii.Direction that the elevation faces (ex. NORTH ELEVATION) viii.the scale used (ex. SCALE 1/4"=1') Page 3: The information required on Page 3 (C) of the drawing includes a.Must note page number and number of pages submitted. (ex. Page 3 of 10) Page 4: The information required on Page 4 of the drawing includes a.Must be labeled "LOCATION MAP" b.Must show NORTH compass/direction arrow. c.Must label sign arrows (A) (B) & (C) d.This business shares lot with other business, therefore the building's frontage must be used not the lots frontage.( make change on application also) |