Inspection History: SIGN SITE REVIEW

Permit Number - T15OT00965

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
08/18/2015 SIGN SITE REVIEW Approved PERMIT READY TO PAY FOR & PICK UP
08/13/2015 SIGN SITE REVIEW Denied WALMART
T15OT00965
REVSION: REV#1
RECEIVED: 8/12/15
REVIEWED: 8/13/15 by Sign Permit Team

APPLICATION & DRAWING DENIED. A revision is required as per Sign Code 3-16.
Revisions required include

Application:
a. Fill in box requesting "FRONTAGE"
b. box requesting "SQUARE FEET" does not match the same info on the drawing.


Drawings:
Page 1 of the drawings submitted must be labeled SIGN (A).
All of the information on the application that pertains to SIGN (A)
must also be on Page 1 (A) of the drawing.
The information required on Page 1 (A) of the drawing includes

1. A written description of SIGN (A)

2. A scaled image of SIGN (A) showing its
a. width & length in "decimal feet" (ex. 3.58') to match application
b. the square footage in "decimal feet" (ex. 24.17 SQ FT) to match application

3. Building elevation drawing: showing the placement of SIGN (A) to scale,
Including the..
a."Over all height" of the top of SIGN (A) in "decimal feet" (ex. OAH 22') to match application
b. Frontage of the building/suite in "decimal feet" (ex. 340') to match application
c. Direction that the elevation faces (ex. SOUTH ELEVATION)

4. A electrical diagram of SIGN (A) showing
a. Type of illumination (ex. LED)
b. draw & label the DISCONNECT SWITCH
c. Indicate the AMPS__ VOLTS__ CIRCUITS__
d. Include the following note " 24 Hour programmable times installed
to comply with the COT outdoor lighting code"

5. Each page must show
a. Name of contractor applying for the permit (ex. Identity)



Page 2 of the drawings submitted must be labeled SIGN (B).
All of the information on the application that pertains to SIGN (B)
must also be on Page 2 (B) of the drawing.
The information required on Page 2 (B) of the drawing includes

2. A written description of SIGN (B)

2. A scaled image of SIGN (B) showing its (SCALE IS WRONG ON DRAWING)
a. width & length in "decimal feet" (ex. 3.58') to match application
b. the square footage in "decimal feet" (ex. 24.17 SQ FT) to match application

3. Building elevation drawing: showing the placement of SIGN (B) to scale,
Including the..
a."Over all height" of the top of SIGN (B) in "decimal feet" (ex. OAH 13') to match application
b. Frontage of the building/suite in "decimal feet" (ex. 340') to match application
c. Direction that the elevation faces (ex. SOUTH ELEVATION)

4. Each page must show
a. Name of contractor applying for the permit (ex. Identity)

Page 3
1. The last page of the submitted packet must be the LOCATION MAP showing
a. A map of the site. (a Google aerial photo is good)
b. Clearly label all adjacent streets
c. A "north directional arrow"
d. The location of all signs (A,B,) on the building with arrows
e. Indicate the frontage length of building/suite in "decimal feet" (ex. 340') to match application

Subject to receipt of corrected plans, additional comments may be forth coming.
08/03/2015 SIGN SITE REVIEW Denied WALMART
T15OT00965
REVSION: NA/ORGINAL
RECEIVED: 7/24/15
REVIEWED: 8/3/15 by Sign Permit Team

APPLICATION & DRAWING DENIED. A revision is required as per Sign Code 3-16.
Revisions required include

Page 1 of the drawings submitted must be marked with an (A).
All of the information on the application that pertains to SIGN (A) must also be on Page 1 (A) of the drawing.
The information required on Page 1 (A) of the drawing includes
1.A written description of SIGN (A)
2.A scaled image of SIGN (A) showing its
a.width & length in "decimal feet" (ex. 3.58') to match application
b.the square footage in "decimal feet" (ex. 24.17 SQ FT) to match application
c.the scale used (ex. SCALE 3/8"=1')
3.A drawing of the building elevation showing the placement of SIGN (A) to scale, showing the
a."Over all height" of the top of SIGN (A) in "decimal feet" (ex. OAH 16.75') to match application
b.Frontage of the building/suite in "decimal feet" (ex. 25') to match application
c.Direction that the elevation faces (ex. NORTH ELEVATION)
d.the scale used (ex. SCALE 1/4"=1')
4.A construction/electrical diagram of SIGN (A) showing
a.Construction details
b.Attachment details (number, size and type of anchors)
c.Materials used in construction of the wall. (ex. Masonry wall)
d.Type of illumination (ex. LED)
e.Show & indicate the DISCONNECT SWITCH
f.Indicate the AMPS__ VOLTS__ CIRCUITS__
g.Include the following note " 24 Hour programmable times installed
to comply with the COT outdoor lighting code"
5.Each page must show
a. Name of contractor applying for the permit (ex. Identity)
b.Must note page number and number of pages submitted. (ex. Page 1 of 3)

Page 2 of the drawings submitted must be marked with an (B).
All of the information on the application that pertains to SIGN (B) must also be on Page 2 (B) of the drawing.
The information required on Page 2 (B) of the drawing includes
1.A written description of SIGN (B)
2.A scaled image of SIGN (B) showing its
a.width & length in "decimal feet" (ex. 3.58') to match appication
b.the square footage in "decimal feet" (ex. 24.17 SQ FT) to match application
c.the scale used (ex. SCALE 3/8"=1')
3.A drawing of the building elevation showing the placement of SIGN (B) to scale, showing the
a."Over all height" of the top of SIGN (B) in "decimal feet" (ex. OAH 16.75') to match application
b.Frontage of the building/suite in "decimal feet" (ex. 25') to match application
c.Direction that the elevation faces (ex. NORTH ELEVATION)
d.the scale used (ex. SCALE 1/4"=1')
4.Each page must show
a. Name of contractor applying for the permit (ex. Identity)
b.Must note page number and number of pages submitted. (ex. Page 2 of 3)

Page 3
1.The last page of the submitted packet must be the LOCATION MAP showing
a.A map of the site. (a Google aerial photo is good)
b. Clearly label all adjacent streets
c.A "north directional arrow"
d.The location of all signs (A,B,C, etc) on the building with arrows
e.Indicate the frontage length of building/suite in "decimal feet" (ex. 25') to match application
Subject to receipt of corrected plans, additional comments may be forth coming.