| 11/20/2015 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL OUT BY TFD: THERE IS FIRE DAMAGE TO A MANUFACTURE HOME: THERE IS INTERIOR AND EXTERIOR DAMAGE TO THE WOOD FRAMING MEMBERS. THE METAL ROOF SHEATHING WAS PEELED BACK AND THE ROOF MEMBERS WERE CUT BACK. IN THIS LOCATION THERE WAS ELECTRICAL CONDUCTORS THAT WERE BURNT AND DAMAGED. THE GAS WATER HEATER COMPARTMENT SUSTAINED THE MOST DAMAGE. THE UNIT WAS BURNED ITS NOW INOPERABLE, THE EXTERIOR WOOD SHEATHING AND EXTERIOR STUDS WERE DAMAGED. THE GAS WATER HEATER COMBUSTIBLE AIR OPENINGS WERE SHEATHED WITH PLYWOOD. THE WOOD SHEATHING WAS INSTALLED WITHOUT PERMITS. THE ELECTRICAL LIFE LINE WAS DISCONNECTED ALL CIRCUIT BREAKERS WERE SHUT OFF. SWG PINNED THE METER OFF. THE UNIT WAS CONDEMNED AND A PLACARD WAS POSTED UNFIT TO OCCUPY. PERMIT ARE REQUIRED FOR ALL REPAIRS. SCHEDULE A 60 DAY FOLLOW UP INSPECTION. |