Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2016 | INSP - FOLLOW UP CODE ENFORCE | Approved | At site, the home is in foreclosure and is being maintained by Safeguard Properties. Close case per supervision. | |
| 12/15/2015 | INSP - FOLLOW UP CODE ENFORCE | Approved | At site, posted a violation placard and NOV on front window. Called property manager Dale, he stated that the owner was going to let the property go into foreclosure. I explained that no one could move into the home until all issues were abated. F/U 180 days. | |
| 11/13/2015 | INSP - FOLLOW UP CODE ENFORCE | Approved | At site, spoke to tenant. They have electric and gas is to be connected later today. F/U 30 days. | |
| 11/10/2015 | INSP - FOLLOW UP CODE ENFORCE | Approved | At site, spoke to tenants. The plumbing is finished and under pressure, but not inspected(?) Called Arco plumbing, spoke to Larry, he stated that they called in to have the plumbing inspected on Friday. No other violations have been address. Called that owner, he stated that he has a management company and I should call them for an update on the repairs. F/U 30 days. | |
| 09/30/2015 | INSP - FOLLOW UP CODE ENFORCE | Approved | At site with Inspector Dan I. We spoke to tenants Julie and Larry. There was a gas leak under the home the home. The tenant contacted Southwest gas. SW gas inform her and the owner that the gas pipe under the home needed to be replace before the gas could be restored. At the home, we found other issues that also need to be corrected. Supply line gas pipe is deteriorated. Pool water is stagnant and green. ELECTRICAL ISSUES: Outside below the panelbox is a broken ground wire. Outside ceiling fan is not properly installed. Outside light switch to fan is not working properly. Outside and inside electrical panelboxes are not labeled or is too faded to read. Dimmer switch in dinning room is not working properly. The light fixture attached to the ceiling fan in the kitchen is loose. Outlet in furnance room is missing a cover. Extension cord wiring is being used to power the disposal under the sink. Electrical counter top outlet by the stove is not working properly. PLUMBING ISSUES: Water leak under the sink. Dishwasher drain hose is lower than the sink, no air gap. Shower stall is missing tiles and the water leaks through the wall next to the toilet. Shut off valve to toilet leaks. The water shut off float inside the toilet tank and flapper not working properly. Toilet in the hallway bathroom doesn't drain properly. Water heater installed without a permit. Water leaks into the home around the hallway bathroom exhaust vent and through the ceiling in the master bedroom when it rains. Property is not registered as a rental with the assessor office. |