Inspection Status: Passed
Inspection History: COT - ENFC - Code Enforcement - Initial
| Date |
Description |
Inspector |
Results |
Comments |
| 09/22/2015 |
COT - ENFC - Code Enforcement - Initial |
GOODMAN |
Approved |
Entered by GOODMAN - VISITED THE SITE, MET WITH OWNER DAVID BESHAM, EXPLAINED THE COMPLAINT AND HOW IT ORIGINATED. ME BASHAM ALLOWED ENTRY INTO THE REAR YARD AREA WHERE I FOUND TWO DIFFERENT ADDITIONS BOTH ON THE SOUTH SIDE OF THE STRUCTURE AND BACK TO BACK. THE PORCH LOOKED PROPERLY CONSTRUCTED. THE LEDGER WAS 2 X 8 NAILED TO THE END TRUSS SITTING ON TOP OF THE WALL. THE ROOF SHEATHING WAS 1/2" OSB OVER 2 X 8 RAFTERS HANGERED INTO THE LEDGER AND SITTING ON TOP OF THE 4 X 8 BEAM THAT SAT ON TOP OF THE 4 X 6 POSTS. ALL POINTS OF ATTACHMENT APPEARED PROPERLY CONNECTED.
THE STORAGE SHED WAS BUILT ON TOP OF THE EXISTING PERIMETER YARD WALL, 2X 4 FRAME WALLS, 2X4 RAFTERS DOUBLED. INFORMED OWNER PLANS WOULD BE REQUIRED AND A DDO MAY BE REQUIRED. |