Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T15DV01417

Parcel: 121040550

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
02/27/2015 INSP - INITIAL CODE ENFORCMENT Approved Received the case from supervisor Rick Saldate. The case is work with out permit. Arrived and work is being done to the house. At this time the house is vacant and secured. Met with the workers and they let me see the work that was being done. While on site the owners rep. called and was able to talk to him and went over the items that need to be addressed. Has a new AC package on the roof where a split system has been removed and replaced. Lacking a water heater where was removed and will be getting a replacement. The windows have been replaced with new and let him know that the sleeping areas will need to be checked for the proper vent opening for the proper size. The kitchen has been remodled and the GFCI's will need to be checked for proper layout. There is new ductwork, electrical, PEX for the plumbing in the shower areas (3), gas lines. The ductwork for the return air is being blocked where the door has been removed. Drywall has been replaced in several areas and the whole interior has been re-textured. Will do N.O.V. RV.