Permit: T15CM07315

Parcel: 134070960


Addresses:

8430 E TIMROD ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/01/2019 FRAMING Approved
02/26/2019 FRAMING Correction Required Strap framing to beam at wall above short block wall and at top plate to beam on perpendicular wall.
Drop ceiling needs filler 2x4 joist to run vertical, not flat, standard framing practice.
Fire blocking required at the drop ceiling ledger line as this new hallway ceiling is a furred space.
02/21/2019 FRAMING Cancelled Canceled
12/11/2018 FRAMING Partial Approval Strap top plates to beam and h2.5 four rafters.
02/28/2018 FRAMING Not ready for Inspection