Permit: T15CM07269

Parcel: 128030680


Addresses:

5772 E SCARLETT ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/27/2015 MECHANICAL - FINAL Approved IVRS - Inspection :*
10/21/2015 MECHANICAL - FINAL Denied PROVIDE A DOUBLE WALL VENT FROM CLOSETH THROUH ROFF W/ AN APPROVED CAP. THE VENTING CONNECTING THE FURNACE IS UPSIDE DOWN.
RPVODE AN OVERFLOW SENSOR.
PROVIDE A SEDIMENT TRAP.
DO NOT PENETRATE CABINET WITH GAS FLEX.
PROVIDE A HOSE CLAMP AT PUMP.
CONNECT OVERFLOW SENSOR ON PUMP.
RELOCATE DISCONNECT FROM BEHIND CONDENSOR.
NO ADHESIVE TAPE ALLOWED OUTDOORS ON LINE SET. USE A PROTECTIVE COATING.
PROVIDE TAMPER PROOF CAPS AT SERVICE POCTS ON CONDENSOR.
BLOCK AND CLAMP PVC EVERY 4' AND PAINT W/ LATEX PAINT. TERMINATE CONSENDATE TO 6" ABOVE GRADE. NEED TO SEE TRAIN HOSE CONNECTION TO PVC.