Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2015 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 10/21/2015 | MECHANICAL - FINAL | Denied | PROVIDE A DOUBLE WALL VENT FROM CLOSETH THROUH ROFF W/ AN APPROVED CAP. THE VENTING CONNECTING THE FURNACE IS UPSIDE DOWN. RPVODE AN OVERFLOW SENSOR. PROVIDE A SEDIMENT TRAP. DO NOT PENETRATE CABINET WITH GAS FLEX. PROVIDE A HOSE CLAMP AT PUMP. CONNECT OVERFLOW SENSOR ON PUMP. RELOCATE DISCONNECT FROM BEHIND CONDENSOR. NO ADHESIVE TAPE ALLOWED OUTDOORS ON LINE SET. USE A PROTECTIVE COATING. PROVIDE TAMPER PROOF CAPS AT SERVICE POCTS ON CONDENSOR. BLOCK AND CLAMP PVC EVERY 4' AND PAINT W/ LATEX PAINT. TERMINATE CONSENDATE TO 6" ABOVE GRADE. NEED TO SEE TRAIN HOSE CONNECTION TO PVC. |