Permit: T15CM07076

Parcel: 127052000


Addresses:

4857 E 4TH ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/24/2016 BUILDING - FINAL Approved IVRS - Inspection :*
06/17/2016 BUILDING - FINAL Denied PROVIDE A 25 AMP BREAKER FOR A/C UNIT.
PROVIDE ACCESS TO WATER HEATER.
WATER LEAKING UNDER KITCHEN SINK.
WATER HEATER VENT NOT TO CODE.
GAS FLEX CANNOT PASS THROUGH A CABINET.
PROVIDE COMB. AIR FOR WATER HTR.
PROVIDE CO2 SENSOR.
PORVIDE ARC FAULT BREAKERS FOR LIGHTING CIRCUITS.
PROVIDE 2'' DUCT LINER IN EXPOSED DUCT.
SECURE ELEC. DISCONNECT.
DO NOT USE WHITE WIRE FOR POWER.


*