Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T15CM06053
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2016 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/23/2016 | FRAMING | Partial Approval | 1ST FLOOR SHAFT; 7TH FLOOR TRASH AND FRESH AIR INTAKE, ROOMS # 601, 602, 604, 606 - FIRE CAULKED. OK TO COVER PROGRESS AREAS. | |
| 10/20/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/20/2016 | FRAMING | Partial Approval | 608,603,610,605,612,607 ok to rock soffits/drop cielings | |
| 10/18/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/18/2016 | FRAMING | Partial Approval | bath shafts ok to cover 6th floor smoke det. location ok on 4th hammer arrest ok on 4th |
|
| 10/17/2016 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 10/11/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/11/2016 | FRAMING | Partial Approval | trash shaft on 3 ok | |
| 10/05/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/05/2016 | FRAMING | Partial Approval | rm 604,bolts too short at beam hardware,fire cualk above closets | |
| 10/05/2016 | FRAMING | Partial Approval | ok for fire lid rms 601,602,603,,east of corr in 604, 604 beam bolts too short at hardware in closet, fire cualk needed above lid in closets | |
| 10/03/2016 | FRAMING | Partial Approval | SHAFTS ON 5TH FLOOR ROOMS 501, 502, 503, 504, 505, 506, 510 OK | |
| 09/28/2016 | FRAMING | Not ready for Inspection | SHAFT ON 5TH FLOOR ARE INCOMPLETE. | |
| 09/27/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/23/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/23/2016 | FRAMING | Partial Approval | 6th floor units ok to rock all but soffits except 601,602,603,604 | |
| 09/20/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/15/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/14/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/14/2016 | FRAMING | Partial Approval | 2nd 3rd floor duct shaft north of elevators ok | |
| 09/12/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/12/2016 | FRAMING | Partial Approval | 405,410,409,407,408,406 ok to energize ok to one side walls 6th floor remove sheetrock from cieling to allow for inspection 6th floor fire barrier |
|
| 09/08/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 09/08/2016 | FRAMING | Partial Approval | 6th floor corridor ok to rock | |
| 09/07/2016 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 09/02/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/31/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/31/2016 | FRAMING | Partial Approval | 1- provide detailed instructions of attachment of eyebrows 6th floor 2-ok to rock exterior walls except at eyebrows |
|
| 08/24/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/24/2016 | FRAMING | Partial Approval | roms 501,502,504,506,508,503,510,505,507 ok to rock except shafts and chases. | |
| 08/19/2016 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 08/18/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/18/2016 | FRAMING | Partial Approval | ok to rock walls and lids in penthouse water heater area | |
| 08/12/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/12/2016 | FRAMING | Partial Approval | ALL 3RD FLOOR ONLY | |
| 08/11/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/05/2016 | FRAMING | Partial Approval | fire stop 406,408 | |
| 08/04/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/04/2016 | FRAMING | Partial Approval | SHEAR WALL NAILING 6TH FLOOR ONLY CHECK CS NAILING 602 AND 606 |
|
| 08/01/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/01/2016 | FRAMING | Partial Approval | RM 406 NAIL PROTECT ELECTRICAL AT MASTER BEDROOM COMPLETE ISLAND WIRING MISSING DRYER VENT LAUNDRY RM 408 MISSING DROPPED CEILING GUEST BEDROOM RM 410 MISSING DROPPED CEILING MASTER CLOSET RM 407 PROVIDE CLEARANCE ALL FIXTURES IN CLOSETS WITHIN 12 " OF SHELVES EDGE MAKE UP EXHAUST FAN LAUNDRY RM 403 CLOSET FIXTURE PENDING FIRE CAULK INFORMATION |
|
| 07/28/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/28/2016 | FRAMING | Partial Approval | DAMAGED FIRE BOCK THROUGHOUT RMS 401,402,404 AND 408 | |
| 07/28/2016 | FRAMING | Partial Approval | COMPLETE DROPPED CEILING RM 408 GUEST BEDROOM | |
| 07/28/2016 | FRAMING | Not ready for Inspection | RM 406 NOT READY FOR INSPECTION | |
| 07/13/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/13/2016 | FRAMING | Partial Approval | exterior walls and party walls 5th floor ok to cover | |
| 07/11/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/11/2016 | FRAMING | Partial Approval | DAMAGED BLOCKING THROUGHOUT 5TH FLOOR | |
| 07/06/2016 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 06/23/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/23/2016 | FRAMING | Partial Approval | 1- 4th floor exterior,party,shear,upper lids &corridor ok to rock. | |
| 06/22/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/15/2016 | FRAMING | Partial Approval | 1- suite 301 provide authorization to drill through beams | |
| 06/13/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/27/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/23/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/03/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/26/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/21/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/19/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/18/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/05/2016 | FRAMING | Not ready for Inspection | ||
| 03/31/2016 | FRAMING | Not ready for Inspection |